smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.31-gentoo-kf0] (local build) Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital RE2-GP Device Model: WDC WD1000FYPS-01ZKB0 Serial Number: WD-WCASJ1640954 LU WWN Device Id: 5 0014ee 256e7a6a6 Firmware Version: 02.01B01 User Capacity: 1,000,203,804,160 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.5, 3.0 Gb/s Local Time is: Fri Sep 30 21:47:46 2016 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (26400) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 302) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 1 3 Spin_Up_Time 0x0003 182 181 021 Pre-fail Always - 7891 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 274 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 010 010 000 Old_age Always - 66140 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 269 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 262 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 3644965 194 Temperature_Celsius 0x0022 123 099 000 Old_age Always - 29 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 SMART Error Log Version: 1 ATA Error Count: 4 CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4 occurred at disk power-on lifetime: 4329 hours (180 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 aa 5c 7c 40 Error: UNC at LBA = 0x007c5caa = 8150186 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 08 40 62 10 7e 0c 00 17:33:34.354 READ FPDMA QUEUED 60 12 40 00 59 10 11 00 17:33:34.354 READ FPDMA QUEUED 60 76 70 8a 59 10 11 00 17:33:34.353 READ FPDMA QUEUED 60 08 90 42 5f b1 0d 00 17:33:34.352 READ FPDMA QUEUED 61 08 90 72 59 10 11 00 17:33:34.351 WRITE FPDMA QUEUED Error 3 occurred at disk power-on lifetime: 3660 hours (152 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 3a 17 dd 40 Error: UNC at LBA = 0x00dd173a = 14489402 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 08 d8 3a 49 59 10 00 9d+01:42:40.462 READ FPDMA QUEUED 60 08 d8 4a 4a 59 10 00 9d+01:42:40.439 READ FPDMA QUEUED 60 08 d8 0a 85 ad 10 00 9d+01:42:40.425 READ FPDMA QUEUED 60 18 70 12 5c 10 11 00 9d+01:42:40.415 READ FPDMA QUEUED 60 08 00 12 d8 0f 11 00 9d+01:42:40.409 READ FPDMA QUEUED Error 2 occurred at disk power-on lifetime: 1381 hours (57 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 25 6a 2d 40 Error: UNC at LBA = 0x002d6a25 = 2976293 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 80 08 00 6a 2d 00 00 12:07:10.493 READ FPDMA QUEUED 2f 00 01 10 00 00 00 00 12:07:09.501 READ LOG EXT 60 80 08 00 6a 2d 00 00 12:07:05.505 READ FPDMA QUEUED 60 80 08 80 69 2d 00 00 12:07:05.484 READ FPDMA QUEUED 60 80 08 00 69 2d 00 00 12:07:05.462 READ FPDMA QUEUED Error 1 occurred at disk power-on lifetime: 1381 hours (57 days + 13 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 25 6a 2d 40 Error: UNC at LBA = 0x002d6a25 = 2976293 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 80 08 00 6a 2d 00 00 12:07:05.505 READ FPDMA QUEUED 60 80 08 80 69 2d 00 00 12:07:05.484 READ FPDMA QUEUED 60 80 08 00 69 2d 00 00 12:07:05.462 READ FPDMA QUEUED 60 80 08 80 68 2d 00 00 12:07:05.442 READ FPDMA QUEUED 60 80 08 00 68 2d 00 00 12:07:05.409 READ FPDMA QUEUED SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 66 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.